SY-B037 Medical Lab Equipment Price Electrophoresis apparatus
Brand Name: Sunnymed
Model Number: SY-B037
Packaging Details: Carton or wooden case, standard export packing
Delivery Detail: In 10 days after payment received
Port: Guangzhou
Brand Name: Sunnymed
Model Number: SY-B037
Packaging Details: Carton or wooden case, standard export packing
Delivery Detail: In 10 days after payment received
Port: Guangzhou
Technical data
Voltage range 0~600V
Current range 0~400mA
Voltage shift ≤0.2%
Current shift ≤0.2%
Working mode Constant current or constant voltage
Output format in four groups synchronously
Power supply 220V±10% 50Hz
Fuse BGXP-5 5A
Operating instructions
1) Connect the output ends to the gel box. The red end is positive electrode (anode) and the black one is
negative electrode (cathode).
2) Revolve the knob of “Adjust” anticlockwise until it stops.
3) Press the button of “Power” to switch on power supply and lighten the digital panel.
4) Choose a constant mode
constant voltage mode
Press the button of “constant T” to turn on the indicator light of “constant T”.
Now the electrophoresis apparatus is working on constant voltage mode.
constant current mode
Press the button of “constant A” to turn on the indicator light of “constant A”.
Now the electrophoresis apparatus is working on constant current mode.
5) Revolve the knob of “Adjust” clockwise gently until it reaches a certain value of voltage or current.
Cautions
1) DO NOT connect the electrophoresis apparatus to the gel box with the power on. Also, DO NOT pull out
the output cables that connecting the apparatus to the gel box with the power on. Always Connect the
electrophoresis apparatus to the gel box BEFORE turning the power supply ON.
2) Assume that you want to set the voltage value to “150V” at the constant voltage mode. If the current value
becomes extremely high or even overflows the rated value (400mA) before you could adjust the voltage value
to 150V, do examine whether the electrophoresis apparatus is well connected to the gel box or the
electrophoresis buffers is accurately prepared.
3) When more than one gel boxes are working together, choose the constant voltage mode to reduce the
interactions between boxes.
4) PULL the power cables OUT OF the power supply when changing the fuse. Specification of the new fuse
should accord with that indicated in “Technical data”
Accessories
1) British power cable 1
2) Output cables 2
3) Operation Manual 1
4) Test report 1
5) Certificate of soundness 1
6) Defects liability card 1
7) “BGXP-5, 5A” fuse 2